Development of poly(3-aminophenylboronic acid) modified graphite rod electrode suitable for fluoride determination

dc.contributor.authorCiftci, Hakan
dc.contributor.authorOztekin, Yasemin
dc.contributor.authorTamer, Ugur
dc.contributor.authorRamanaviciene, Almira
dc.contributor.authorRamanavicius, Arunas
dc.date.accessioned2020-06-25T18:12:10Z
dc.date.available2020-06-25T18:12:10Z
dc.date.issued2014
dc.departmentKırıkkale Üniversitesi
dc.descriptionTamer, Ugur/0000-0001-9989-6123; Ramanavicius, Arunas/0000-0002-0885-3556
dc.description.abstractPoly(3-aminophenylboronic acid), (PAPBA) film was formed on the graphite rod surface by potential cycling. The PAPBA-modified graphite rod (PAPBA/GR) electrode prepared in this way was used for potentiometric fluoride determination. The linear calibration range was from 5 x 10(-4) to 5 x 10(-2) M with the slope of the linear part of the calibration curve of 42.5 mV/log C. No interference effect of the most common ions such as sodium, potassium, chloride, nitrate, iodide, calcium, zinc, aluminum, sulfate and sorbitol was observed during electrochemical determination of fluoride. On the other hand, the PAPBA/GR electrode showed not only good sensitivity and selectivity, but also relatively rapid response to changes of analyte concentrations in the range of 20 s. The sensor was successfully applied for fluoride determination in real sample - toothpaste. (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipLithuanian Scientific Council [TRY-055]en_US
dc.description.sponsorshipThis work was financially supported by Lithuanian Scientific Council, Project number TRY-055.en_US
dc.identifier.citationclosedAccessen_US
dc.identifier.doi10.1016/j.talanta.2014.03.018
dc.identifier.endpage207en_US
dc.identifier.issn0039-9140
dc.identifier.issn1873-3573
dc.identifier.pmid24881554
dc.identifier.scopus2-s2.0-84899628272
dc.identifier.scopusqualityQ1
dc.identifier.startpage202en_US
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2014.03.018
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5772
dc.identifier.volume126en_US
dc.identifier.wosWOS:000337866200028
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherElsevier Science Bven_US
dc.relation.ispartofTalanta
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPoly(3-aminophenylboronic acid)en_US
dc.subjectFluorideen_US
dc.subjectPotentiometryen_US
dc.subjectConducting polymeren_US
dc.subjectIon-selective electrodeen_US
dc.titleDevelopment of poly(3-aminophenylboronic acid) modified graphite rod electrode suitable for fluoride determinationen_US
dc.typeArticle

Files

Original bundle
Now showing 1 - 1 of 1
[ X ]
Name:
Development of poly(3-aminophenylboronic acid) modified graphite rod electrode suitable for fluoride determination.pdf
Size:
821.86 KB
Format:
Adobe Portable Document Format
Description:
Tam Metin/Full Text