dc.description.abstractA 4 month-old, 1.9 kg, female, Scottish fold cat was brought to Kirikkale University Veterinary Faculty Research and Practice Hospital with complaints of progressive dyspnea and exercise intolerance. Dorsal deformation in the caudal part of the sternum and displacement of the heart into the left hemithorax were determined in the clinical and radiographic examinations. In the measurements made on the radiographic images taken before the operation, the frontosagittal index (FSI) and vertebral index (VI) values were measured as 3.5 and 5.1, respectively. An external splint made of PVC material is fixed to the thorax with suture material passed around the sternebrae, in order to correct the sternal malposition in intraoperative treatment. The patient was followed for 8 weeks after the operation. The external splint was removed five weeks after the operation, and the FSI and VI values were measured as 1.4 and 11.3 on the radiographs, respectively. In the postoperative period, it was observed that the patient's problems such as dyspnea and exercise intolerance disappeared. In animals with bone development yet to be completed, it has been determined that external splint application gives successful results.
dc.identifier.doi10.33988/auvfd.1083564
dc.identifier.endpage358
dc.identifier.issn1300-0861
dc.identifier.issn1308-2817
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85163658661
dc.identifier.scopusqualityQ3
dc.identifier.startpage353
dc.identifier.trdizinid1183556
dc.identifier.urihttps://doi.org/10.33988/auvfd.1083564
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay1183556
dc.identifier.urihttps://hdl.handle.net/20.500.12587/23830
dc.identifier.volume70
dc.identifier.wosWOS:001021320100014
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.publisherAnkara Univ
dc.relation.ispartofAnkara Universitesi Veteriner Fakultesi Dergisi
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20241229
dc.subjectExternal splint; Cat; Pectus excavatum
dc.titleOpen surgical correction combined with an u-shaped external splint for pectus excavatum in a Scottish fold cat
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Tam Metin/Full Text
Boyut:
1.28 MB
Biçim:
Adobe Portable Document Format