A simple method to improve adenoma detection rate during colonoscopy: Altering patient position

dc.contributor.authorKoksal, Aydin Seref
dc.contributor.authorKalkan, Ismail Hakki
dc.contributor.authorTorun, Serkan
dc.contributor.authorTaskiran, Ismail
dc.contributor.authorOztas, Erkin
dc.contributor.authorKayacetin, Ertugrul
dc.contributor.authorSasmaz, Nurgul
dc.date.accessioned2020-06-25T18:07:03Z
dc.date.available2020-06-25T18:07:03Z
dc.date.issued2013
dc.departmentKırıkkale Üniversitesi
dc.description.abstractBACKGROUND: Colonoscopy is currently considered to be the gold standard method for detecting and removing adenomatous polyps. However, tandem colonoscopy studies reveal a pooled polyp miss rate of 22%. OBJECTIVE: A prospective randomized trial was conducted to assess whether alteration of patient position during colonoscopy withdrawal increases the adenoma detection rate (ADR). METHOD: The study group included 120 patients who presented for elective colonoscopic examination. After reaching the cecum, patients were randomly assigned in a 1: 1 ratio to examination in either the left lateral position or other positions (left lateral position for the cecum, ascending colon and hepatic flexure; supine for transverse colon; and supine and right lateral position for splenic flexure, descending and sigmoid colon) first. Examination of the colon was performed segment by segment. The size, morphology and location of all polyps were recorded. Polyps were removed immediately after examination of a colon segment when all positions were completed. ADR and polyp detection rates (PDR) were calculated. RESULTS: A total of 102 patients completed the study. Examination in the left lateral position revealed 66 polyps in 31 patients (PDR 30.3%) and 42 adenomas in 24 patients (ADR 23.5%). PDR increased to 43.1% (81 polyps in 44 patients) and the ADR to 33.3% (53 adenomas in 34 patients) after the colon was examined in the additional positions (P< 0.001 and P= 0.002, respectively). The increase in the number of adenomas detected was statistically significant in the transverse and sigmoid colon. The addition of position changes led to a 9.8% increase in the ADR in the transverse colon, splenic flexure, and descending and sigmoid colon. The frequency of surveillance interval was shortened in nine (8.8%) patients after examination of the colon in dynamic positions. CONCLUSION: Alteration of patient position during colonoscopy withdrawal is a simple and effective method to improve ADR.en_US
dc.identifier.citationAydin Şeref Köksal, İsmail Hakkı Kalkan, Serkan Torun, İsmail Taşkıran, Erkin Öztaş, Ertuğrul Kayaçetin, Nurgül Şaşmaz,(2013). "A Simple Method to Improve Adenoma Detection Rate During Colonoscopy: Altering Patient Position", Canadian Journal of Gastroenterology and Hepatology, vol. 27(9), 509-512.en_US
dc.identifier.endpage512en_US
dc.identifier.issn0835-7900
dc.identifier.issue9en_US
dc.identifier.pmid24078934
dc.identifier.scopus2-s2.0-84884378858
dc.identifier.scopusqualityN/A
dc.identifier.startpage509en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12587/5457
dc.identifier.volume27en_US
dc.identifier.wosWOS:000328163700004
dc.identifier.wosqualityQ3
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherPulsus Group Incen_US
dc.relation.ispartofCanadian Journal Of Gastroenterology
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdenoma detection rateen_US
dc.subjectAdenomatous polypen_US
dc.subjectColonen_US
dc.subjectColonoscopyen_US
dc.titleA simple method to improve adenoma detection rate during colonoscopy: Altering patient positionen_US
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
A simple method to improve adenoma detection rate during colonoscopy Altering patient position.pdf
Boyut:
1.71 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin/Full Text